Depth 70mm | Width 150mm | Height 84mm
This textile inspection system features an intelligent length counter with 485-Modbus communication for real-time data tracking. The digital display allows easy adjustment of units, length settings, and preset values, while seamless ERP integration enables automated production reporting.
Seamless ERP Integration
High-Performance Operation
Panel Function Description
1、Roll Length Display
Displays with 2 decimal places
2、Roll Speed
3、Reset Current
Current value → 0,The accumulated total remains unchanged
4、View Tota
Hold [Valid] + [Total]Displays total
4、Reset Total
Press [Reset] + [Total] + [Valid]Clears all totals
5、Display Preset
Hold [Valid] + [Preset Length]Shows preset value
5、Set Preset
Press and hold the “Valid” and “Preset Length” buttons for 5 seconds to enter preset length setting mode (indicated by flashing digital display). Use the “Meter Unit (+1)” and “Yard Unit (Shift Right)” buttons to adjust values. The system automatically saves settings and returns to normal operation after 5 seconds of inactivity.
6、Display Circumference
Hold [Valid] + [Circumference]Shows current value
6、Set Circumference
Press and hold the “Valid” and “Circumference” buttons for 5 seconds to enter circumference setting mode (indicated by flashing digital display). Use the “Meter Unit (+1)” and “Yard Unit (Shift Right)” buttons to adjust values. The system automatically saves settings and returns to normal operation after 5 seconds of inactivity.
7、Meter Unit
Press and hold “Valid” and “Meter Unit” to switch to metric display. In setting mode (indicated by flashing light), each press increases the value by 1, resetting to 0 when maximum is reached.
8、Yard Unit
Press and hold “Valid” and “Yard Unit” to switch to yard display. In setting mode (indicated by flashing light), each press shifts the cursor right by one digit, returning to the starting position after reaching the rightmost digit.
Pulse Display
Hold [Valid] + [Circumference] + [Preset Length]Shows current pulses
Pulse Setting
Press and hold “Valid”, “Circumference”, and “Preset Length” for 5 seconds to enter pulse count setting mode. Use the “Meter Unit (+1)” and “Yard Unit (Shift Right)” buttons to adjust values. The system automatically saves settings and returns to normal operation after 5 seconds of inactivity.
Wiring Instructions
1
Clear-
2
Clear+
3
OV Blue
4
InB Yellow
5
InA Black
6
12V Black
7
Common
8
NC
9
NO
10
Earth
11
220 V/N
12
220 V/L
13
A
14
B
15
OV
16
Stop
17
12V
Contact Us
0512-63599187
Address: East Side of Xiaoping Avenue, Badu, Zhenze Town, Wujiang District, Suzhou City, Jiangsu Province, China